FLUSHLINE SYSTEM

Fire Rated System icon represents approvals and listings with accredited laboratories. Color Match Options icon represents a choice between standard, custom or project specific color matching. ADA Compliant icon represents systems that comply with the Americans with Disabilities Act guideline. No-Bump System icon represents expansion joints that provide flush, no-bump floor-to-floor transitions. Corner Condition icon represents availability of corner condition floor, wall and ceiling expansion joints.

FSSR Nominal "JT"
Joint Opening "JT"
Total Movement
Sight Line "SL"
Seismic Min.
Thermal Min.
Thermal Max.
Seismic Max.
FSSR-100 1.0" 25 0.750" 19 0.750" 19 1.125" 29 1.375" 35 0.625" 16 1.063" 27
FSSR-150 1.5" 38 1.188" 30 1.188" 30 1.625" 41 1.625" 41 0.438" 11 1.438" 37
FSSR-200 2.0" 51 1.438" 37 1.500" 38 2.500" 64 2.500" 64 1.063" 27 2.063" 52
FSSR-250 2.5" 64 1.875" 48 1.875" 48 2.938" 75 2.938" 75 1.063" 27 2.563" 65
FSSR-300 3.0" 76 2.250" 57 2.250" 57 3.500" 89 3.688" 94 1.438" 37 2.500" 64